Stainless Ultrasonic Bulk Water Meter DN80 – BMAG Meter
The BMAG Stainless Ultrasonic Bulk Water Meter DN80 is a stainless-steel, flange-ended, dual-channel ultrasonic flow meter engineered for district metering areas (DMA), industrial water intake lines, and utility bulk billing. With no moving parts, an IP68-sealed body, and a wide R250 measuring range, it delivers billing-grade accuracy in raw, potable, and reclaimed water — and pairs natively with LoRaWAN, NB-IoT, M-Bus, or RS485 AMR systems, so utilities and OEM system integrators can drop it straight into an existing smart-metering deployment.
| مادة | الفولاذ المقاوم للصدأ |
|---|---|
| Meter Size | DN50=2", DN65=2½", DN80=3", DN100=4", DN100+ |
| نسبة | R500، R630، R630، R800، R400 |
| وحدة القياس | قدم مكعب، متر مكعب، جالون، لتر |
Stainless Ultrasonic Bulk Water Meter DN80
ميزة عداد المياه السائبة بالموجات فوق الصوتية
- Dual-Channel Ultrasonic Measurement: Two independent channels cross-verify every reading. If one channel is blocked by debris or air, the meter still delivers a valid reading — no unplanned downtime for a DMA billing cycle.
- Stainless-Steel Body with Flanged Ends: Corrosion-resistant SS body with standard DN80 PN16 flanges — drops into existing utility pipework without adapters, and stands up to raw and reclaimed water long-term.
- No Moving Parts, No Wear: Full-bore ultrasonic path means zero mechanical wear, negligible pressure loss (≤ 0.025 MPa), and stable accuracy over the meter’s 10+ year service life.
- Wide Dynamic Range R250 (R400 available) : Accurate metering from very low leakage-detection flows up to peak DN80 demand — ideal for night-flow analysis in leak detection programs.
- IP68 Fully Submersible: The meter head and transducer housings are sealed against water ingress. Deploy in flooded pits, vaults, or below-grade chambers without an added enclosure.
- 10-Year Battery Life: Built-in DC 3.6 V lithium battery keeps the meter running for the full billing lifecycle — no field battery swaps between MID recertifications.
- AMR/AMI-Ready Communication: Choose from RS485 Modbus, M-Bus, pulse output, LoRaWAN, or NB-IoT at the order stage. External antenna included for buried installations.
- Reverse Flow Detection: Bidirectional measurement with separate forward and reverse totalizers — supports interconnection points where flow direction alternates.
- Onboard Data Logging: Stores 2 years of daily consumption plus 24 monthly totals, so audit and dispute resolution do not require an always-on connection.
- Low Straight-Pipe Requirement (U0/D0) : Installs in constrained chambers where a mechanical meter cannot meet its straight-run requirement.
ظروف عمل مقياس المياه السائبة بالموجات فوق الصوتية
- درجة الحرارة: متاح للمياه الباردة 0-50 درجة مئوية (32℉-122℉)
- الضغط: .61.6MPa (16 بار)
تصميم وجه الطلب
الأبعاد

| مقاس | L | W | H | D | D1 | ن*م |
|---|---|---|---|---|---|---|
| مم | الكمية | |||||
| DN50 | 200 | 165 | 225 | 165 | 125 | 4*M16 |
| DN65 | 200 | 185 | 230 | 185 | 145 | 4*M16 |
| DN80 | 225 | 200 | 240 | 200 | 160 | 8*M16 |
| DN100 | 250 | 220 | 250 | 220 | 180 | 8*M16 |
| DN125 | 250 | 250 | 250 | 250 | 210 | 8*M16 |
| DN150 | 300 | 285 | 310 | 285 | 240 | 8*M20 |
| DN200 | 350 | 340 | 360 | 340 | 295 | 12*M20 |
| DN250 | 450 | 405 | 410 | 405 | 355 | 12*M24 |
| DN300 | 500 | 460 | 450 | 460 | 410 | 12*M24 |
معلومات تقنية
| مقاس | مم | د ن 50 | Dn65 | Dn80 | Dn100 | Dn125 | Dn150 | Dn200 | Dn250 | Dn300 |
|---|---|---|---|---|---|---|---|---|---|---|
| R | Q₃/ Q₁ | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 |
| س4 | متر مكعب/ساعة | 50 | 50 | 78.75 | 125 | 200 | 312.5 | 500 | 787.5 | 1250 |
| Q₃ | متر مكعب/ساعة | 40 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | 1000 |
| Q₂ | L/h | 160 | 160 | 252 | 400 | 640 | 1000 | 1600 | 2520 | 4000 |
| Q₁ | L/h | 100 | 100 | 157-5 | 250 | 400 | 625 | 1000 | 1575 | 2500 |
| الحد الأقصى للقراءة | m³ | الحد الأقصى للقراءة 99999999.9999.9999 التبديل التلقائي إلى 99999999.99 بعد اكتمال النطاق 99999999.99 |
||||||||
| الحد الأدنى للقراءة | لتر | 0.1 | ||||||||
| الحد الأدنى للقراءة (التحقق) | لتر | 0.01 | ||||||||
| فقدان الضغط | △p | △p10 | ||||||||
| الحد الأقصى للضغط | الخريطة | MAP16 | ||||||||
| درجة الحرارة القصوى | ℃ | T30 أوT50 | ||||||||
| تثبيت | / | أي منصب | ||||||||
| فئات حساسية التدفق الجانبي للتدفق | / | أوو دو | ||||||||
| المناخ والبيئة الميكانيكية | 0 | |||||||||
| البيئة الكهرومغناطيسية | E2 | |||||||||
R=Q3/Q1 Optional:400/500/630/800
الأعلى. خطأ في الإذن:
- من Q1 شاملاً إلى ولكن باستثناء Q2 هو ± 5%
- من Q2 شاملاً وحتى Q4 هو ± 2% لـ T30 و± 3% لـ T50

ملكنا 35000 متر مربع منشأة و 20+ سنة تجربة العودة لدينا 10 سنوات ضمان الجودة.