DN100 Flange Connection Water Meter Woltman WP-SDC B
BMAG DN100 Flange Connection Water Meter. R200.
| Material | Cast Iron |
|---|---|
| Size | DN40-DN300 |
| Connect | Flange |
| Ratio | R80, R160, R200 |
| Pulse | Optional |
| Coating | Optional |
Product Overview
Key Features
Ultra-High Precision
Adopts advanced Woltman turbine measuring mechanism to ensure high metering accuracy compliant with ISO 4064 and OIML R49 standards. It provides reliable data for billing, monitoring, and process control.
Wide Measurement Range
Features an extended flow range with low starting flow and high overload tolerance. It performs consistently in both low‑flow and high‑flow pipeline scenarios, covering full‑range water usage monitoring.
Exceptional Durability
Constructed with heavy‑duty cast iron with anti‑corrosion coating for outstanding wear, impact, and pressure resistance. Rated for 1.6 MPa working pressure, it ensures long service life in harsh industrial and outdoor environments.
Smart-Ready Design
Pre‑configured for seamless integration with remote reading systems, pulse output modules, RS485, M‑Bus, and IoT monitoring platforms. It supports digital transformation and smart water management.
Technical Specifications
- Product Name: DN50 Flange Connection Water Meter
- Body Material: Cast Iron
- Measurement Accuracy: R200
- Pressure Loss: Δ25
- Nominal Diameter: DN40–DN300 (DN50 standard)
- Connection Type: Flange Connection
- Working Pressure: 1.6 MPa (16 bar)
- Key Advantages: Ultra‑High Precision | Wide Measurement Range | Exceptional Durability | Smart‑Ready Design
Pulse output always ready, and Pulse output AS OPTION:
- The Pulse Output Device consists of a plastic housing with a Reed Switch, and 1,5 m cable with 2 cores in Red and Black
- Capacity of the Pulse Emitter:
Size m3 /pulse DN40 to DN125 0.01/0.1/1 DN150 to DN300 0.1/1/10
Working Conditions
- Temperature: Available for cold water 0-50 ℃
- Pressure: ≤1.6MPa ( 16bars)
Standards Compliance
- ISO4064:2014/OIML R49
- Directive 2014/32/EU on measuring instruments
- European Standard EN14154
Turbine Woltman Water Meter Dial Plate Design
- Dial Plate Design can be as per customer’s design
- Follow is an example of DN50 BMAG Woltman Water Meter with R200
MAX. PERMISSION ERROR:
- From Q1 inclusive up to but excluding Q2 is ± 5%
- From Q2 inclusive up to and including Q4 is ± 2% for T30 and ± 3% for T50