{"id":5207,"date":"2024-10-14T09:29:31","date_gmt":"2024-10-14T09:29:31","guid":{"rendered":"https:\/\/www.bmagmeter.com\/?p=5207"},"modified":"2024-10-15T08:09:24","modified_gmt":"2024-10-15T08:09:24","slug":"comprensione-delle-portate-dei-contatori-dacqua-q1-q2-q3-q4-e-del-rapporto-r","status":"publish","type":"post","link":"https:\/\/www.bmagmeter.com\/it\/understanding-water-meter-flow-rates-q1-q2-q3-q4-and-r-ratio\/","title":{"rendered":"Comprendere le portate dei contatori d'acqua (Q1, Q2, Q3, Q4) e il rapporto R"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><a href=\"#What-is-Water-Meter-Flow-Rate\">1. Che cos'\u00e8 la portata del contatore dell'acqua?<\/a><br>    <a href=\"#Flow-Rate-Calculation\">1.1Calcolo della portata<\/a><br>    <a href=\"#Testing-Water-Meter-Flow-Rates\">1.2Test delle portate dei contatori dell'acqua<\/a><br><a href=\"#What-is-R-Ratio-in-Water-Meters\">2. Che cos'\u00e8 il rapporto R nei misuratori d'acqua?<\/a><br>    <a href=\"#Calculating Flow Rates Using R-Ratio\">2.1Calcolo della portata con il rapporto R<\/a><br>    <a href=\"http:\/\/R80\/R160\/R200-Datasheet\">Scheda tecnica 2.2R80\/R160\/R200<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Che cosa significano le portate di un contatore d'acqua (Q<sub>1<\/sub>, Q<sub>2<\/sub>, Q<sub>3<\/sub>, Q<sub>4<\/sub>)?  Che cosa rappresenta R: Q3\/Q1? Siete curiosi di conoscere questa domanda di scrittura? Diamo un'occhiata ad alcune competenze sui contatori dell'acqua.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"614\" height=\"600\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio.webp\" alt=\"Comprendere le portate dei contatori d&#039;acqua (Q1, Q2, Q3, Q4) e il rapporto R\" class=\"wp-image-5209\" style=\"width:500px\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio.webp 614w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio-300x293.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio-12x12.webp 12w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio-600x586.webp 600w\" sizes=\"(max-width: 614px) 100vw, 614px\" \/><figcaption class=\"wp-element-caption\">Comprendere le portate dei contatori d'acqua (Q1, Q2, Q3, Q4) e il rapporto R<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"What-is-Water-Meter-Flow-Rate\">Qual \u00e8 la portata del contatore dell'acqua (Q<sub>1<\/sub>, Q<sub>2<\/sub>, Q<sub>3<\/sub>, Q<sub>4<\/sub>)\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le portate dei contatori d'acqua sono parametri fondamentali che definiscono il campo operativo e l'accuratezza di un contatore.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1 (portata minima)<\/strong><br>Q<sub>1<\/sub>, noto anche come Q<sub>min<\/sub>\u00e8 la portata minima alla quale il contatore d'acqua deve funzionare entro l'errore massimo consentito (MPE). Questa portata \u00e8 fondamentale per rilevare piccole perdite e misurare con precisione il basso consumo di acqua.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Portata minima alla quale il misuratore deve funzionare entro gli errori massimi consentiti - ISO 4064<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2 (portata transitoria)<\/strong><br>Q<sub>2<\/sub>, o Qt, \u00e8 la portata che divide il campo del misuratore in due zone: la superiore (Q<sub>3<\/sub>) e inferiore(Q<sub>1<\/sub>) zone di portata. Ogni zona ha le proprie caratteristiche MPE. Q<sub>2<\/sub> \u00e8 sempre 1,6 volte il Q1, come da standard internazionali.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Portata compresa tra la portata permanente e la portata minima che divide l'intervallo di portata in due zone, la zona di portata superiore e la zona di portata inferiore, ciascuna caratterizzata dai propri errori massimi ammissibili - ISO 4064<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3 (portata permanente)<\/strong><br>Q3, indicata anche come Qn o Qp, \u00e8 la portata pi\u00f9 elevata nell'ambito delle condizioni operative nominali a cui si prevede che il contatore funzioni accuratamente per un lungo periodo. Questa \u00e8 in genere la portata utilizzata per designare le dimensioni del contatore.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Portata massima all'interno delle condizioni operative nominali a cui il misuratore deve funzionare entro gli errori massimi consentiti - ISO 4064<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4 (portata di sovraccarico)<\/strong><br>Q<sub>4<\/sub>, o Q<sub>massimo<\/sub>\u00e8 la portata massima alla quale il misuratore pu\u00f2 funzionare per un breve periodo mantenendo le sue prestazioni metrologiche. Di solito \u00e8 pari a 1,25 volte Q<sub>3<\/sub>.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Portata massima alla quale il misuratore deve funzionare per un breve periodo di tempo entro gli errori massimi consentiti, mantenendo le sue prestazioni metrologiche quando viene successivamente utilizzato nelle condizioni operative nominali - ISO 4064<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Terminologia aggiuntiva sulla portata:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Qs (portata iniziale)<\/strong>: La portata alla quale la lancetta del misuratore inizia a muoversi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Qx (portata di commutazione del contatore combinato)<\/strong>: Applicabile ai contatori composti, \u00e8 la portata alla quale il contatore pi\u00f9 grande si ferma o inizia a funzionare.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"Flow-Rate-Calculation\">Calcolo della portata:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La portata volumetrica (Q) \u00e8 calcolata come Q = dV\/dt, dove V \u00e8 il volume d'acqua e t \u00e8 il tempo impiegato da questo volume per passare attraverso il contatore.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"576\" height=\"150\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/BAMG-water-meter-flow-rate-Q-formula.webp\" alt=\"Formula della portata Q del contatore d&#039;acqua BAMG\" class=\"wp-image-5210\" style=\"width:400px\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/BAMG-water-meter-flow-rate-Q-formula.webp 576w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/BAMG-water-meter-flow-rate-Q-formula-300x78.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/BAMG-water-meter-flow-rate-Q-formula-18x5.webp 18w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><figcaption class=\"wp-element-caption\">portata Q del contatore d'acqua formula<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"Testing-Water-Meter-Flow-Rates\">Verifica della portata dei contatori dell'acqua:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prendendo come esempio un contatore d'acqua DN15, ecco come vengono tipicamente testate le diverse portate:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Portata iniziale: Aumentare gradualmente il flusso da zero fino a quando si osserva un movimento continuo della lancetta.<br>Portata minima: Passaggio di 1 litro d'acqua a Q<sub>1<\/sub>(portata minima) e calcolare l'errore.<br>Portata transitoria: Passare 2L di acqua a Q<sub>2<\/sub>(portata di transizione) e calcolare l'errore.<br>Portata permanente: Passare 50L di acqua a Q<sub>3<\/sub>(portata permanente) e calcolare l'errore.<br>Portata di sovraccarico: Passaggio di 100L di acqua a Q<sub>4<\/sub> (portata di sovraccarico) e calcolare l'errore.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nota: i volumi d'acqua possono essere regolati in base alla precisione del banco di prova del contatore dell'acqua.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"What-is-R-Ratio-in-Water-Meters\">Che cos'\u00e8 il rapporto R nei contatori d'acqua?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Il rapporto R, un indicatore cruciale dell'accuratezza del contatore dell'acqua, \u00e8 la portata permanente (Q<sub>3<\/sub>) rispetto alla portata minima (Q<sub>1<\/sub>). Rappresenta effettivamente il campo di misura e la precisione del misuratore. R=Q<sub>3<\/sub>\/Q<sub>1<\/sub><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"Calculating-Flow-Rates-Using-R-Ratio\">Calcolo delle portate con il rapporto R:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Consideriamo un esempio di un misuratore con classe di precisione R160<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q<sub>3<\/sub>(Portata permanente) = 2.500 l\/h:<br>Q<sub>4<\/sub> (Portata massima) = 1,25 \u00d7 Q3 = 3.125 l\/h<br>Q<sub>1<\/sub> (portata minima) = Q<sub>3<\/sub> \/ 160 = 15,625 l\/h<br>Q<sub>2<\/sub> (Portata di transizione) = 1,6 \u00d7 Q<sub>1<\/sub> = 25 l\/h<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"R80\/R160\/R200-Datasheet\">Scheda tecnica R80\/R160\/R200<\/h2>\n\n\n\n<style type=\"text\/css\">\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-18eh{border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-te0j{background-color:#c0c0c0;border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-mqa1{border-color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n<\/style>\n<table class=\"tg\" style=\"undefined;table-layout: fixed; width: 574px\"><colgroup>\n<col style=\"width: 88px\">\n<col style=\"width: 58px\">\n<col style=\"width: 66px\">\n<col style=\"width: 71px\">\n<col style=\"width: 71px\">\n<col style=\"width: 68px\">\n<col style=\"width: 73px\">\n<col style=\"width: 79px\">\n<\/colgroup>\n<thead>\n  <tr>\n    <th class=\"tg-te0j\" rowspan=\"2\">Misurare<\/th>\n    <th class=\"tg-te0j\" rowspan=\"2\">mm<\/th>\n    <th class=\"tg-te0j\">Dn15<\/th>\n    <th class=\"tg-te0j\">Dn20<\/th>\n    <th class=\"tg-te0j\">Dn25<\/th>\n    <th class=\"tg-te0j\">Dn32<\/th>\n    <th class=\"tg-te0j\">Dn40<\/th>\n    <th class=\"tg-te0j\">Dn50<\/th>\n  <\/tr>\n  <tr>\n    <th class=\"tg-te0j\" colspan=\"6\">R80<\/th>\n  <\/tr><\/thead>\n<tbody>\n  <tr>\n    <td class=\"tg-18eh\">Q4<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">3,125<\/td>\n    <td class=\"tg-18eh\">5,000<\/td>\n    <td class=\"tg-18eh\">7,875<\/td>\n    <td class=\"tg-18eh\">12,500<\/td>\n    <td class=\"tg-18eh\">20,000<\/td>\n    <td class=\"tg-18eh\">31,250<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q3<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">2,500<\/td>\n    <td class=\"tg-18eh\">4,000<\/td>\n    <td class=\"tg-18eh\">6,300<\/td>\n    <td class=\"tg-18eh\">10,000<\/td>\n    <td class=\"tg-18eh\">16,000<\/td>\n    <td class=\"tg-18eh\">25,000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q2<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">50 <\/td>\n    <td class=\"tg-18eh\">80 <\/td>\n    <td class=\"tg-18eh\">126 <\/td>\n    <td class=\"tg-18eh\">200 <\/td>\n    <td class=\"tg-18eh\">320 <\/td>\n    <td class=\"tg-18eh\">500 <\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q1<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-wa1i\">31.25 <\/td>\n    <td class=\"tg-wa1i\">50 <\/td>\n    <td class=\"tg-wa1i\">78.75<\/td>\n    <td class=\"tg-wa1i\">125 <\/td>\n    <td class=\"tg-wa1i\">200 <\/td>\n    <td class=\"tg-wa1i\">312.5 <\/td>\n  <\/tr>\n<\/tbody><\/table>\n\n\n\n<style type=\"text\/css\">\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-18eh{border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-te0j{background-color:#c0c0c0;border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-mqa1{border-color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n<\/style>\n<table class=\"tg\" style=\"undefined;table-layout: fixed; width: 574px\"><colgroup>\n<col style=\"width: 88px\">\n<col style=\"width: 58px\">\n<col style=\"width: 66px\">\n<col style=\"width: 71px\">\n<col style=\"width: 71px\">\n<col style=\"width: 68px\">\n<col style=\"width: 73px\">\n<col style=\"width: 79px\">\n<\/colgroup>\n<thead>\n  <tr>\n    <th class=\"tg-te0j\" rowspan=\"2\">Misurare<\/th>\n    <th class=\"tg-te0j\" rowspan=\"2\">mm<\/th>\n    <th class=\"tg-te0j\">Dn15<\/th>\n    <th class=\"tg-te0j\">Dn20<\/th>\n    <th class=\"tg-te0j\">Dn25<\/th>\n    <th class=\"tg-te0j\">Dn32<\/th>\n    <th class=\"tg-te0j\">Dn40<\/th>\n    <th class=\"tg-te0j\">Dn50<\/th>\n  <\/tr>\n  <tr>\n    <th class=\"tg-te0j\" colspan=\"6\">R160<\/th>\n  <\/tr><\/thead>\n<tbody>\n  <tr>\n    <td class=\"tg-18eh\">Q4<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">3,125<\/td>\n    <td class=\"tg-18eh\">5,000<\/td>\n    <td class=\"tg-18eh\">7,875<\/td>\n    <td class=\"tg-18eh\">12,500<\/td>\n    <td class=\"tg-18eh\">20,000<\/td>\n    <td class=\"tg-18eh\">31,250<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q3<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">2,500<\/td>\n    <td class=\"tg-18eh\">4,000<\/td>\n    <td class=\"tg-18eh\">6,300<\/td>\n    <td class=\"tg-18eh\">10,000<\/td>\n    <td class=\"tg-18eh\">16,000<\/td>\n    <td class=\"tg-18eh\">25,000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q2<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">25 <\/td>\n    <td class=\"tg-18eh\">40 <\/td>\n    <td class=\"tg-18eh\">63 <\/td>\n    <td class=\"tg-18eh\">100 <\/td>\n    <td class=\"tg-18eh\">160 <\/td>\n    <td class=\"tg-18eh\">250 <\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q1<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">15.63 <\/td>\n    <td class=\"tg-18eh\">25 <\/td>\n    <td class=\"tg-18eh\">39.375<\/td>\n    <td class=\"tg-18eh\">62.5 <\/td>\n    <td class=\"tg-18eh\">100 <\/td>\n    <td class=\"tg-18eh\">156.3 <\/td>\n  <\/tr>\n<\/tbody><\/table>\n\n\n\n<style type=\"text\/css\">\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-18eh{border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-te0j{background-color:#c0c0c0;border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-mqa1{border-color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n<\/style>\n<table class=\"tg\" style=\"undefined;table-layout: fixed; width: 574px\"><colgroup>\n<col style=\"width: 88px\">\n<col style=\"width: 58px\">\n<col style=\"width: 66px\">\n<col style=\"width: 71px\">\n<col style=\"width: 71px\">\n<col style=\"width: 68px\">\n<col style=\"width: 73px\">\n<col style=\"width: 79px\">\n<\/colgroup>\n<thead>\n  <tr>\n    <th class=\"tg-te0j\" rowspan=\"2\">Misurare<\/th>\n    <th class=\"tg-te0j\" rowspan=\"2\">mm<\/th>\n    <th class=\"tg-te0j\">Dn15<\/th>\n    <th class=\"tg-te0j\">Dn20<\/th>\n    <th class=\"tg-te0j\">Dn25<\/th>\n    <th class=\"tg-te0j\">Dn32<\/th>\n    <th class=\"tg-te0j\">Dn40<\/th>\n    <th class=\"tg-te0j\">Dn50<\/th>\n  <\/tr>\n  <tr>\n    <th class=\"tg-te0j\" colspan=\"6\">R200<\/th>\n  <\/tr><\/thead>\n<tbody>\n  <tr>\n    <td class=\"tg-18eh\">Q4<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">3,125<\/td>\n    <td class=\"tg-18eh\">5,000<\/td>\n    <td class=\"tg-18eh\">7,875<\/td>\n    <td class=\"tg-18eh\">12,500<\/td>\n    <td class=\"tg-18eh\">20,000<\/td>\n    <td class=\"tg-18eh\">31,250<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q3<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">2,500<\/td>\n    <td class=\"tg-18eh\">4,000<\/td>\n    <td class=\"tg-18eh\">6,300<\/td>\n    <td class=\"tg-18eh\">10,000<\/td>\n    <td class=\"tg-18eh\">16,000<\/td>\n    <td class=\"tg-18eh\">25,000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q2<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">20 <\/td>\n    <td class=\"tg-18eh\">32 <\/td>\n    <td class=\"tg-18eh\">50.4 <\/td>\n    <td class=\"tg-18eh\">80 <\/td>\n    <td class=\"tg-18eh\">128 <\/td>\n    <td class=\"tg-18eh\">200 <\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q1<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-wa1i\">12.5 <\/td>\n    <td class=\"tg-wa1i\">20 <\/td>\n    <td class=\"tg-wa1i\">31.5 <\/td>\n    <td class=\"tg-wa1i\">50 <\/td>\n    <td class=\"tg-wa1i\">80 <\/td>\n    <td class=\"tg-wa1i\">125 <\/td>\n  <\/tr>\n<\/tbody><\/table>\n\n\n\n<p class=\"wp-block-paragraph\">Si prega di notare che questi sono i risultati misurati in base allo standard. Se la misurazione viene eseguita in condizioni non standard, i risultati saranno diversi. Ad esempio, il collaudo di un contatore dell'acqua installato verticalmente in un banco di prova orizzontale determiner\u00e0 una minore precisione e un intervallo di errore pi\u00f9 ampio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">BMAG offre <a href=\"https:\/\/www.bmagmeter.com\/it\/prodotti\/\"><strong>Contatori d'acqua R80-R400<\/strong><\/a> per soddisfare le vostre esigenze.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Connettiti con il nostro\u00a0<a href=\"https:\/\/www.bmagmeter.com\/it\/contattaci\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Il team del servizio clienti<\/strong><\/a>\u00a0per richiedere campioni e discutere le nostre politiche flessibili di ordine minimo.<\/p>","protected":false},"excerpt":{"rendered":"<p>1. What is\u00a0Water Meter Flow Rate\uff1f 1.1Flow Rate Calculation 1.2Testing Water Meter Flow Rates2. What is\u00a0R-Ratio in Water Meters? 2.1Calculating Flow Rates Using R-Ratio 2.2R80\/R160\/R200 Datasheet What do a water meter&#8217;s Flow Rates (Q1, Q2, Q3, Q4) represent? What does R: Q3\/Q1 stand for? Are you curious about this writing question? Let&#8217;s take a look [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":5211,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[120],"tags":[],"class_list":["post-5207","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/posts\/5207","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/comments?post=5207"}],"version-history":[{"count":0,"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/posts\/5207\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/media\/5211"}],"wp:attachment":[{"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/media?parent=5207"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/categories?post=5207"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bmagmeter.com\/it\/wp-json\/wp\/v2\/tags?post=5207"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}