{"id":5207,"date":"2024-10-14T09:29:31","date_gmt":"2024-10-14T09:29:31","guid":{"rendered":"https:\/\/www.bmagmeter.com\/?p=5207"},"modified":"2024-10-15T08:09:24","modified_gmt":"2024-10-15T08:09:24","slug":"understanding-water-meter-flow-rates-q1-q2-q3-q4-and-r-ratio","status":"publish","type":"post","link":"https:\/\/www.bmagmeter.com\/ms\/understanding-water-meter-flow-rates-q1-q2-q3-q4-and-r-ratio\/","title":{"rendered":"Understanding Water Meter Flow Rates (Q1, Q2, Q3, Q4) and R-Ratio"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><a href=\"#What-is-Water-Meter-Flow-Rate\">1. What is\u00a0Water Meter Flow Rate\uff1f<\/a><br>    <a href=\"#Flow-Rate-Calculation\">1.1Flow Rate Calculation<\/a><br>    <a href=\"#Testing-Water-Meter-Flow-Rates\">1.2Testing Water Meter Flow Rates<\/a><br><a href=\"#What-is-R-Ratio-in-Water-Meters\">2. What is\u00a0R-Ratio in Water Meters?<\/a><br>    <a href=\"#Calculating Flow Rates Using R-Ratio\">2.1Calculating Flow Rates Using R-Ratio<\/a><br>    <a href=\"http:\/\/R80\/R160\/R200-Datasheet\">2.2R80\/R160\/R200 Datasheet<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What do a water meter&#8217;s Flow Rates (Q<sub>1<\/sub>, Q<sub>2<\/sub>, Q<sub>3<\/sub>, Q<sub>4<\/sub>) represent?  What does R: Q3\/Q1 stand for? Are you curious about this writing question? Let&#8217;s take a look at some water meter expertise.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"614\" height=\"600\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio.webp\" alt=\"Understanding Water Meter Flow Rates (Q1, Q2, Q3, Q4) and R-Ratio\" class=\"wp-image-5209\" style=\"width:500px\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio.webp 614w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio-300x293.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio-12x12.webp 12w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/Understanding-Water-Meter-Flow-Rates-Q1-Q2-Q3-Q4-and-R-Ratio-600x586.webp 600w\" sizes=\"(max-width: 614px) 100vw, 614px\" \/><figcaption class=\"wp-element-caption\">Understanding Water Meter Flow Rates (Q1, Q2, Q3, Q4) and R-Ratio<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"What-is-Water-Meter-Flow-Rate\">What is\u00a0Water Meter Flow Rate (Q<sub>1<\/sub>, Q<sub>2<\/sub>, Q<sub>3<\/sub>, Q<sub>4<\/sub>)\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Water meter flow rates are fundamental parameters that define a meter&#8217;s operational range and accuracy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1 (Minimum Flow Rate)<\/strong><br>Q<sub>1<\/sub>, also known as Q<sub>min<\/sub>, is the lowest flow rate at which the water meter is required to operate within the maximum permissible error (MPE). This flow rate is critical for detecting small leaks and measuring low water usage accurately.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Lowest flow rate at which the meter is to operate within the maximum permissible errors &#8212; ISO 4064<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2 (Transitional Flow Rate)<\/strong><br>Q<sub>2<\/sub>, or Qt, is the flow rate that divides the meter&#8217;s range into two zones: the upper(Q<sub>3<\/sub>)\u00a0and lower(Q<sub>1<\/sub>)\u00a0flow rate zones. Each zone has its own MPE characteristics. Q<sub>2<\/sub> is always 1.6 times Q1, as per international standards.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Flow rate between the permanent flow rate and the minimum flow rate that divides the flow rate\u00a0range into two zones, the upper flow rate zone and the lower flow rate zone, each characterized\u00a0by its own maximum permissible errors &#8212; ISO 4064<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3 (Permanent Flow Rate)<\/strong><br>Q3, also referred to as Qn or Qp, is the highest flow rate within the rated operating conditions at which the meter is expected to function accurately\u00a0over a long period. This is typically the flow rate used to designate the meter size.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Highest flow rate within the rated operating conditons at which the meter is to operate within the\u00a0maximum permissible errors &#8212; ISO 4064<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4 (Overload Flow Rate)<\/strong><br>Q<sub>4<\/sub>, or Q<sub>max<\/sub>, is the highest flow rate at which the meter can operate for a short period while maintaining its metrological performance. It&#8217;s usually 1.25 times Q<sub>3<\/sub>.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Highest flow rate at which the meter is to operate for a short period of time within the max imum\u00a0permissible errors, while maintaining its metrological performance when it is subsequently\u00a0operating within the rated operating conditions &#8212; ISO 4064<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Flow Rate Terminology:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Qs (Starting Flow Rate)<\/strong>: The flow rate at which the meter&#8217;s pointer begins to move.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Qx (Combination Meter Changeover Flow Rate)<\/strong>: Applicable to compound meters, it&#8217;s the flow rate at which the larger meter stops or starts operating.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"Flow-Rate-Calculation\">Flow Rate Calculation:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The volumetric flow rate (Q) is calculated as Q = dV\/dt, where V is the volume of water and t is the time taken for this volume to pass through the meter.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"576\" height=\"150\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/BAMG-water-meter-flow-rate-Q-formula.webp\" alt=\"BAMG water meter flow rate Q formula\" class=\"wp-image-5210\" style=\"width:400px\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/BAMG-water-meter-flow-rate-Q-formula.webp 576w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/BAMG-water-meter-flow-rate-Q-formula-300x78.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/10\/BAMG-water-meter-flow-rate-Q-formula-18x5.webp 18w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><figcaption class=\"wp-element-caption\">water meter flow rate Q formula<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"Testing-Water-Meter-Flow-Rates\">Testing Water Meter Flow Rates:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Using a DN15 water&nbsp;meter as an example, here&#8217;s how different flow rates are typically tested:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Starting Flow Rate: Gradually increase flow from zero until continuous pointer movement is observed.<br>Minimum Flow Rate: Pass 1L of water at Q<sub>1<\/sub>(Minimum Flow Rate) and calculate the error.<br>Transitional Flow Rate: Pass 2L of water at Q<sub>2<\/sub>(Transitional Flow Rate) and calculate the error.<br>Permanent Flow Rate: Pass 50L of water at Q<sub>3<\/sub>(Permanent Flow Rate) and calculate the error.<br>Overload Flow Rate: Pass 100L of water at Q<sub>4<\/sub> (Overload Flow Rate)and calculate the error.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Note: Water volumes may be adjusted based on the precision of the water meter testing bench.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"What-is-R-Ratio-in-Water-Meters\">What is&nbsp;R-Ratio in Water Meters?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The R-ratio, a crucial indicator of water meter accuracy, is the permanent flow rate (Q<sub>3<\/sub>) ratio to the minimum flow rate (Q<sub>1<\/sub>). It effectively represents the meter&#8217;s measuring range and precision. R=Q<sub>3<\/sub>\/Q<sub>1<\/sub><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"Calculating-Flow-Rates-Using-R-Ratio\">Calculating Flow Rates Using R-Ratio:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Let&#8217;s consider an example of a meter with R160 accuracy class<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q<sub>3<\/sub>(Permanent Flow Rate)\u00a0= 2,500 l\/h:<br>Q<sub>4<\/sub> (Maximum Flow Rate) = 1.25 \u00d7 Q3 = 3,125 l\/h<br>Q<sub>1<\/sub> (Minimum Flow Rate) = Q<sub>3<\/sub> \/ 160 = 15.625 l\/h<br>Q<sub>2<\/sub> (Transitional Flow Rate) = 1.6 \u00d7 Q<sub>1<\/sub> = 25 l\/h<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"R80\/R160\/R200-Datasheet\">R80\/R160\/R200 Datasheet<\/h2>\n\n\n\n<style type=\"text\/css\">\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-18eh{border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-te0j{background-color:#c0c0c0;border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-mqa1{border-color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n<\/style>\n<table class=\"tg\" style=\"undefined;table-layout: fixed; width: 574px\"><colgroup>\n<col style=\"width: 88px\">\n<col style=\"width: 58px\">\n<col style=\"width: 66px\">\n<col style=\"width: 71px\">\n<col style=\"width: 71px\">\n<col style=\"width: 68px\">\n<col style=\"width: 73px\">\n<col style=\"width: 79px\">\n<\/colgroup>\n<thead>\n  <tr>\n    <th class=\"tg-te0j\" rowspan=\"2\">Saiz<\/th>\n    <th class=\"tg-te0j\" rowspan=\"2\">mm<\/th>\n    <th class=\"tg-te0j\">Dn15<\/th>\n    <th class=\"tg-te0j\">Dn20<\/th>\n    <th class=\"tg-te0j\">Dn25<\/th>\n    <th class=\"tg-te0j\">Dn32<\/th>\n    <th class=\"tg-te0j\">Dn40<\/th>\n    <th class=\"tg-te0j\">Dn50<\/th>\n  <\/tr>\n  <tr>\n    <th class=\"tg-te0j\" colspan=\"6\">R80<\/th>\n  <\/tr><\/thead>\n<tbody>\n  <tr>\n    <td class=\"tg-18eh\">Q4<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">3,125<\/td>\n    <td class=\"tg-18eh\">5,000<\/td>\n    <td class=\"tg-18eh\">7,875<\/td>\n    <td class=\"tg-18eh\">12,500<\/td>\n    <td class=\"tg-18eh\">20,000<\/td>\n    <td class=\"tg-18eh\">31,250<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q3<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">2,500<\/td>\n    <td class=\"tg-18eh\">4,000<\/td>\n    <td class=\"tg-18eh\">6,300<\/td>\n    <td class=\"tg-18eh\">10,000<\/td>\n    <td class=\"tg-18eh\">16,000<\/td>\n    <td class=\"tg-18eh\">25,000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q2<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">50 <\/td>\n    <td class=\"tg-18eh\">80 <\/td>\n    <td class=\"tg-18eh\">126 <\/td>\n    <td class=\"tg-18eh\">200 <\/td>\n    <td class=\"tg-18eh\">320 <\/td>\n    <td class=\"tg-18eh\">500 <\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q1<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-wa1i\">31.25 <\/td>\n    <td class=\"tg-wa1i\">50 <\/td>\n    <td class=\"tg-wa1i\">78.75<\/td>\n    <td class=\"tg-wa1i\">125 <\/td>\n    <td class=\"tg-wa1i\">200 <\/td>\n    <td class=\"tg-wa1i\">312.5 <\/td>\n  <\/tr>\n<\/tbody><\/table>\n\n\n\n<style type=\"text\/css\">\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-18eh{border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-te0j{background-color:#c0c0c0;border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-mqa1{border-color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n<\/style>\n<table class=\"tg\" style=\"undefined;table-layout: fixed; width: 574px\"><colgroup>\n<col style=\"width: 88px\">\n<col style=\"width: 58px\">\n<col style=\"width: 66px\">\n<col style=\"width: 71px\">\n<col style=\"width: 71px\">\n<col style=\"width: 68px\">\n<col style=\"width: 73px\">\n<col style=\"width: 79px\">\n<\/colgroup>\n<thead>\n  <tr>\n    <th class=\"tg-te0j\" rowspan=\"2\">Saiz<\/th>\n    <th class=\"tg-te0j\" rowspan=\"2\">mm<\/th>\n    <th class=\"tg-te0j\">Dn15<\/th>\n    <th class=\"tg-te0j\">Dn20<\/th>\n    <th class=\"tg-te0j\">Dn25<\/th>\n    <th class=\"tg-te0j\">Dn32<\/th>\n    <th class=\"tg-te0j\">Dn40<\/th>\n    <th class=\"tg-te0j\">Dn50<\/th>\n  <\/tr>\n  <tr>\n    <th class=\"tg-te0j\" colspan=\"6\">R160<\/th>\n  <\/tr><\/thead>\n<tbody>\n  <tr>\n    <td class=\"tg-18eh\">Q4<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">3,125<\/td>\n    <td class=\"tg-18eh\">5,000<\/td>\n    <td class=\"tg-18eh\">7,875<\/td>\n    <td class=\"tg-18eh\">12,500<\/td>\n    <td class=\"tg-18eh\">20,000<\/td>\n    <td class=\"tg-18eh\">31,250<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q3<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">2,500<\/td>\n    <td class=\"tg-18eh\">4,000<\/td>\n    <td class=\"tg-18eh\">6,300<\/td>\n    <td class=\"tg-18eh\">10,000<\/td>\n    <td class=\"tg-18eh\">16,000<\/td>\n    <td class=\"tg-18eh\">25,000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q2<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">25 <\/td>\n    <td class=\"tg-18eh\">40 <\/td>\n    <td class=\"tg-18eh\">63 <\/td>\n    <td class=\"tg-18eh\">100 <\/td>\n    <td class=\"tg-18eh\">160 <\/td>\n    <td class=\"tg-18eh\">250 <\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q1<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">15.63 <\/td>\n    <td class=\"tg-18eh\">25 <\/td>\n    <td class=\"tg-18eh\">39.375<\/td>\n    <td class=\"tg-18eh\">62.5 <\/td>\n    <td class=\"tg-18eh\">100 <\/td>\n    <td class=\"tg-18eh\">156.3 <\/td>\n  <\/tr>\n<\/tbody><\/table>\n\n\n\n<style type=\"text\/css\">\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-18eh{border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-te0j{background-color:#c0c0c0;border-color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-mqa1{border-color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n<\/style>\n<table class=\"tg\" style=\"undefined;table-layout: fixed; width: 574px\"><colgroup>\n<col style=\"width: 88px\">\n<col style=\"width: 58px\">\n<col style=\"width: 66px\">\n<col style=\"width: 71px\">\n<col style=\"width: 71px\">\n<col style=\"width: 68px\">\n<col style=\"width: 73px\">\n<col style=\"width: 79px\">\n<\/colgroup>\n<thead>\n  <tr>\n    <th class=\"tg-te0j\" rowspan=\"2\">Saiz<\/th>\n    <th class=\"tg-te0j\" rowspan=\"2\">mm<\/th>\n    <th class=\"tg-te0j\">Dn15<\/th>\n    <th class=\"tg-te0j\">Dn20<\/th>\n    <th class=\"tg-te0j\">Dn25<\/th>\n    <th class=\"tg-te0j\">Dn32<\/th>\n    <th class=\"tg-te0j\">Dn40<\/th>\n    <th class=\"tg-te0j\">Dn50<\/th>\n  <\/tr>\n  <tr>\n    <th class=\"tg-te0j\" colspan=\"6\">R200<\/th>\n  <\/tr><\/thead>\n<tbody>\n  <tr>\n    <td class=\"tg-18eh\">Q4<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">3,125<\/td>\n    <td class=\"tg-18eh\">5,000<\/td>\n    <td class=\"tg-18eh\">7,875<\/td>\n    <td class=\"tg-18eh\">12,500<\/td>\n    <td class=\"tg-18eh\">20,000<\/td>\n    <td class=\"tg-18eh\">31,250<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q3<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">2,500<\/td>\n    <td class=\"tg-18eh\">4,000<\/td>\n    <td class=\"tg-18eh\">6,300<\/td>\n    <td class=\"tg-18eh\">10,000<\/td>\n    <td class=\"tg-18eh\">16,000<\/td>\n    <td class=\"tg-18eh\">25,000<\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q2<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-18eh\">20 <\/td>\n    <td class=\"tg-18eh\">32 <\/td>\n    <td class=\"tg-18eh\">50.4 <\/td>\n    <td class=\"tg-18eh\">80 <\/td>\n    <td class=\"tg-18eh\">128 <\/td>\n    <td class=\"tg-18eh\">200 <\/td>\n  <\/tr>\n  <tr>\n    <td class=\"tg-18eh\">Q1<\/td>\n    <td class=\"tg-mqa1\">  l\/h<\/td>\n    <td class=\"tg-wa1i\">12.5 <\/td>\n    <td class=\"tg-wa1i\">20 <\/td>\n    <td class=\"tg-wa1i\">31.5 <\/td>\n    <td class=\"tg-wa1i\">50 <\/td>\n    <td class=\"tg-wa1i\">80 <\/td>\n    <td class=\"tg-wa1i\">125 <\/td>\n  <\/tr>\n<\/tbody><\/table>\n\n\n\n<p class=\"wp-block-paragraph\">Please note that these are the results when measured according to the standard. If the measurement is performed under non-standard conditions, the results will be different. For example, testing a vertically installed water meter in a horizontal test bench will result in reduced accuracy and a wider error range.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">BMAG offers <a href=\"https:\/\/www.bmagmeter.com\/ms\/products\/\"><strong>R80-R400 water meters<\/strong><\/a> to meet your needs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Berhubung dengan kami\u00a0<a href=\"https:\/\/www.bmagmeter.com\/ms\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>pasukan khidmat pelanggan<\/strong><\/a>\u00a0untuk meminta sampel dan membincangkan dasar pesanan minimum fleksibel kami.<\/p>","protected":false},"excerpt":{"rendered":"<p>1. What is\u00a0Water Meter Flow Rate\uff1f 1.1Flow Rate Calculation 1.2Testing Water Meter Flow Rates2. What is\u00a0R-Ratio in Water Meters? 2.1Calculating Flow Rates Using R-Ratio 2.2R80\/R160\/R200 Datasheet What do a water meter&#8217;s Flow Rates (Q1, Q2, Q3, Q4) represent? What does R: Q3\/Q1 stand for? Are you curious about this writing question? Let&#8217;s take a look [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":5211,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[120],"tags":[],"class_list":["post-5207","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/posts\/5207","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/comments?post=5207"}],"version-history":[{"count":0,"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/posts\/5207\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/media\/5211"}],"wp:attachment":[{"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/media?parent=5207"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/categories?post=5207"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bmagmeter.com\/ms\/wp-json\/wp\/v2\/tags?post=5207"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}