{"id":4643,"date":"2024-09-13T08:42:56","date_gmt":"2024-09-13T08:42:56","guid":{"rendered":"https:\/\/www.bmagmeter.com\/?p=4643"},"modified":"2026-05-15T13:32:20","modified_gmt":"2026-05-15T05:32:20","slug":"water-meter-anti-magnetic-testing-methods-and-standards-a-global-perspective","status":"publish","type":"post","link":"https:\/\/www.bmagmeter.com\/tr\/water-meter-anti-magnetic-testing-methods-and-standards-a-global-perspective\/","title":{"rendered":"How to Test the Magnetic Resistance of Water Meter?\u200b &#8211; Anti-Magnetic Water Meter"},"content":{"rendered":"<p class=\"wp-block-paragraph\">As a seasoned expert in the water meter industry, BMAG witnessed the evolution of Water Meter Anti-Magnetic Testing Methods and Standards. This article delves into the critical aspects of these standards and their implementation across the globe.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Origins of Anti-Magnetic Standards for Water Meters<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The establishment of anti-magnetic standards for water meters emerged in the mid to late 20th century when magnetic interference became a significant threat to water meter accuracy. As permanent magnet technology advanced, some individuals began using strong magnetic fields to interfere with water meter operations, leading to inaccurate measurements and substantial losses for water utilities.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In response to this challenge, water meter standard-setting bodies worldwide began to focus on and research anti-magnetic technologies.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote has-text-align-left is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><em>&#8220;All water meters where the mechanical components may be influenced by a static magnetic field (e.g. equipped with a magnetic coupling in the drive to the readout or with a magnet-driven pulse output) and all meters with electronic components shall be tested to show that they are able to withstand the influence of a static magnetic field.&#8221;<\/em><br>                                                                        &#8212; Quote from ISO 4064-2-2014 &#8211; 7.12 Magnetic field testing<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">This quote underscores the importance of Water Meter Anti-Magnetic Testing Methods in ensuring meter reliability.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"898\" height=\"730\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/magnetic-fields.webp\" alt=\"\" class=\"wp-image-4825\" style=\"width:400px\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/magnetic-fields.webp 898w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/magnetic-fields-300x244.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/magnetic-fields-768x624.webp 768w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/magnetic-fields-15x12.webp 15w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/magnetic-fields-600x488.webp 600w\" sizes=\"(max-width: 898px) 100vw, 898px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Problems Addressed by Anti-Magnetic Standards<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Improved Measurement Accuracy: Preventing external magnetic fields from interfering with normal water meter operation<\/li>\n\n\n\n<li>Reduced Water Resource Waste: Curbing water theft through magnetic interference<\/li>\n\n\n\n<li>Protection of Water Utility Interests: Ensuring the accuracy of water fee collection<\/li>\n\n\n\n<li>Enhanced Water Meter Reliability: Extending meter lifespan and reducing maintenance costs<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Comparison of Major Global Water Meter Anti-Magnetic Standards<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">European Standard (EN 14154-3):<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Requirement: &#8220;The water meter shall be able to withstand a magnetic field of 100 kA\/m \u00b1 5 % applied for 15 minutes without showing any deformation, malfunction, or change in its metrological characteristics.&#8221;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">International Standard (ISO 4064-2:2014):<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Requirement: &#8220;The water meter shall withstand a magnetic field with a magnetic flux density of at least 100 mT, generated by a permanent magnet with a surface area of 1000 mm\u00b2 \u00b1 10 %, applied to the most sensitive locations on the meter&#8217;s surface for a period of 1 min.&#8221;<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"1007\" height=\"745\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/iso-4064-2-2014-8.16-Static-magnetic-field-8.16.1-Test-conditions.webp\" alt=\"Water Meter Anti-Magnetic Testing iso-4064-2-2014 8.16 Static magnetic field 8.16.1 Test conditions\" class=\"wp-image-4823\" style=\"width:800px\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/iso-4064-2-2014-8.16-Static-magnetic-field-8.16.1-Test-conditions.webp 1007w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/iso-4064-2-2014-8.16-Static-magnetic-field-8.16.1-Test-conditions-300x222.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/iso-4064-2-2014-8.16-Static-magnetic-field-8.16.1-Test-conditions-768x568.webp 768w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/iso-4064-2-2014-8.16-Static-magnetic-field-8.16.1-Test-conditions-16x12.webp 16w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/iso-4064-2-2014-8.16-Static-magnetic-field-8.16.1-Test-conditions-600x444.webp 600w\" sizes=\"(max-width: 1007px) 100vw, 1007px\" \/><figcaption class=\"wp-element-caption\">Water Meter Anti-Magnetic Testing<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">American Water Works Association Standard (AWWA C700 series):<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Requirement: &#8220;Meters shall be able to withstand an external magnetic field of 3,000 Gauss without damage to the meter or a change in accuracy of more than 1.5 percent.&#8221;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Standards Commonalities:<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Although the interference magnetic field strength requirements vary among standards, all standards emphasize that external magnetic fields should not affect the meter&#8217;s measurement accuracy. Testing methods generally employ permanent magnets or electromagnetic devices. Standards require comparison of measurement errors before and after applying magnetic fields, most other requirements are similar, aside from the magnetic field strength.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Detailed Water Meter Anti-Magnetic Testing Method<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\" style=\"margin-top:var(--wp--preset--spacing--40);margin-right:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40);margin-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"We Put Magnets on a Water Meter \u2014 Watch What Happens\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/3OZuHqZFi2k?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Using ISO 4064-2:2014 as an example, the specific testing steps are as follows:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">a) Preparation:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Calibrate the test water meter<br>Prepare magnetic field generation device meeting standard requirements<br>Prepare flow testing equipment<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">b) Initial Error Test:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Test meter measurement error at different flow rates under normal conditions<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">c) Magnetic Field Application:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Apply specified magnetic field strength to meter surface<br>Magnetic field should cover key areas such as counter and sensor regions<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><a href=\"https:\/\/www.bwmagnets.com\/Ferrite-Magnet-Ring-pd46162565.html\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" width=\"800\" height=\"666\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Water-Meter-Anti-Magnetic-Testing-Ferrite-Magnet-Ring.webp\" alt=\"Water Meter Anti-Magnetic Testing Ferrite Magnet Ring\" class=\"wp-image-4853\" style=\"width:400px\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Water-Meter-Anti-Magnetic-Testing-Ferrite-Magnet-Ring.webp 800w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Water-Meter-Anti-Magnetic-Testing-Ferrite-Magnet-Ring-300x250.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Water-Meter-Anti-Magnetic-Testing-Ferrite-Magnet-Ring-768x639.webp 768w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Water-Meter-Anti-Magnetic-Testing-Ferrite-Magnet-Ring-14x12.webp 14w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Water-Meter-Anti-Magnetic-Testing-Ferrite-Magnet-Ring-600x500.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><figcaption class=\"wp-element-caption\"><a href=\"https:\/\/www.bwmagnets.com\/Ferrite-Magnet-Ring-pd46162565.html\" target=\"_blank\" rel=\"noopener\">Water Meter Anti-Magnetic Testing Ferrite Magnet Ring<\/a><\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">d) Error Test Under Magnetic Field:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Repeat measurement error tests at different flow rates under magnetic field influence<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">e) Post-Removal Test:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Remove the magnetic field and retest the meter error to ensure no permanent damage<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">f) Data Analysis:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Compare error data from initial, under magnetic field, and post-removal tests<br>Ensure error changes are within the standard allowable range<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.bmagmeter.com\/tr\/urun\/anti-magnetic-water-meter\/\">BMAG anti-magnetic water meters<\/a> are produced and tested strictly with anti-magnetic standards, fully meeting all requirements. We welcome customers to inquire and place orders.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" data-id=\"4858\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01-1024x1024.webp\" alt=\"BMAG Anti-Magnetic Multi Jet Water Meter 01\" class=\"wp-image-4858\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01-1024x1024.webp 1024w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01-300x300.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01-150x150.webp 150w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01-768x768.webp 768w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01-12x12.webp 12w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01-600x600.webp 600w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01-100x100.webp 100w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Multi-Jet-Water-Meter-01.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">BMAG Anti-Magnetic Multi Jet Water Meter<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" data-id=\"4820\" src=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Water-Meter-01-1024x1024.webp\" alt=\"BMAG Anti-Magnetic Single Jet Water Meter\" class=\"wp-image-4820\" srcset=\"https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Water-Meter-01-1024x1024.webp 1024w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Water-Meter-01-300x300.webp 300w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Water-Meter-01-150x150.webp 150w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Water-Meter-01-768x768.webp 768w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Water-Meter-01-12x12.webp 12w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/elementor\/thumbs\/Anti-Magnetic-Water-Meter-01-qtzk9r34slphh1x3sud5fgzp8z3vm0o5vqp7gsxgfk.webp 600w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Water-Meter-01-100x100.webp 100w, https:\/\/www.bmagmeter.com\/wp-content\/uploads\/2024\/09\/Anti-Magnetic-Water-Meter-01.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">BMAG Anti-Magnetic Single Jet Water Meter<\/figcaption><\/figure>\n<\/figure>\n\n\n\n<div class=\"wp-block-buttons popup 1895 is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-3e41869c wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popupinquiry\"><a class=\"wp-block-button__link wp-element-button\">Get A Free Inquiry<\/a><\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Conclusion<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Establishing and implementing anti-magnetic water-meter standards have greatly improved their reliability and measurement accuracy. As an industry expert, I believe future development trends will focus on:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Research and development of more powerful anti-magnetic materials and technologies<br>Application of intelligent anti-magnetic systems<br>Further unification of global standards<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">References:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">European Standard EN 14154-3: <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/cen\/3a7c1b7e-5f7f-4d3f-8f5e-9b2b7b3a8e1d\/en-14154-3-2005a1-2007\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">https:\/\/standards.iteh.ai\/catalog\/standards\/cen\/3a7c1b7e-5f7f-4d3f-8f5e-9b2b7b3a8e1d\/en-14154-3-2005a1-2007<\/a><br>ISO 4064-2:2014: <a href=\"https:\/\/www.iso.org\/standard\/59754.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">https:\/\/www.iso.org\/standard\/59754.html<\/a><br>GB\/T 778.2-2018: <a href=\"http:\/\/openstd.samr.gov.cn\/bzgk\/gb\/newGbInfo?hcno=A48F4E90F2C97FB001B50925DD51F540\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">http:\/\/openstd.samr.gov.cn\/bzgk\/gb\/newGbInfo?hcno=A48F4E90F2C97FB001B50925DD51F540<\/a><br>AWWA C700 Series Standards: <a href=\"https:\/\/www.awwa.org\/Publications\/Standards\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">https:\/\/www.awwa.org\/Publications\/Standards<\/a><br>Recent_Advances_in_Anti-magnetic: <a href=\"https:\/\/www.researchgate.net\/publication\/337684189_Recent_Advances_in_Anti-magnetic_Tampering_Technologies_for_Water_Meters\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">https:\/\/www.researchgate.net\/publication\/337684189_Recent_Advances_in_Anti-magnetic_Tampering_Technologies_for_Water_Meters<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>As a seasoned expert in the water meter industry, BMAG witnessed the evolution of Water Meter Anti-Magnetic Testing Methods and Standards. This article delves into the critical aspects of these standards and their implementation across the globe. Origins of Anti-Magnetic Standards for Water Meters The establishment of anti-magnetic standards for water meters emerged in the [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":4822,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[120],"tags":[],"class_list":["post-4643","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/posts\/4643","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/comments?post=4643"}],"version-history":[{"count":2,"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/posts\/4643\/revisions"}],"predecessor-version":[{"id":8054,"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/posts\/4643\/revisions\/8054"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/media\/4822"}],"wp:attachment":[{"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/media?parent=4643"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/categories?post=4643"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bmagmeter.com\/tr\/wp-json\/wp\/v2\/tags?post=4643"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}